In the Filter Tab you can --

set the conditions of displayed trace or the conditions of tracing. 
  The default is Display. 

2. Three kinds of address/data mode can be chose:
	Range allows you to enter an  address/data range with start address and end address. 
	Multiple allows you to enter up to 10 address/data (wildcard is not allowed in this case) separated with comma. 
	Wildcard allows a wildcard address/data.
The status combo is five processor status code (as defined in the table below) to specify status code to be matched as part of the event condition.
Code	Status
S	Instruction
F	Program memory read
R	Data memory read
W	Data memory write
AK	Interrupt acknowledge
Defining A Trace Buffer Trigger
To define a trace buffer trigger, do any of the following:
 From the Group menu choose the Trace command and switch to the Trigger tab. 
 From the Trace menu in the Trace window, choose the Trigger command. 
 From the shortcut menu in the Trace window, choose the Trigger command.
 